GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 602307  Size: SH
  1. Disconnect the exhaust gas recirculation (EGR) electrical connector.
  2. Remove the EGR valve retaining nuts and bolts.
  3. Important: Inspect the EGR passages in the crossover water pump housing for deposits. Clean the EGR passages as needed. Refer to Exhaust Gas Recirculation (EGR) System Cleaning .

  4. Remove the EGR valve.
  5. Clean the EGR valve mounting surface.

Installation Procedure


    Object Number: 602307  Size: SH
  1. Install the cleaned or the replacement EGR valve using a new gasket.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the EGR valve retaining nuts and bolts.
  4. Tighten
    Tighten the retaining nuts and bolts to 24 N·m (18 lb ft).

  5. Reconnect the EGR valve electrical connector.