DTC Descriptors

DTC P2452 03: Diesel Particulate Filter Differential Pressure Sensor Circuit Voltage Below Threshold

DTC P2452 07: Diesel Particulate Filter Differential Pressure Sensor Circuit Voltage Above Threshold

DTC P2454: Diesel Particulate Filter Differential Pressure Sensor Circuit Low Voltage

DTC P2455: Diesel Particulate Filter Differential Pressure Sensor Circuit High Voltage

Circuit/System Description

The diesel exhaust after-treatment system consists of an under hood pre-catalytic converter and an underbody catalytic converter. The underbody catalytic converter also consists of the main Diesel Oxidation Catalyst (DOC) and the coated Diesel Particulate Filter (DPF). One of the main purposes of the DPF is to collect particulates from the engine exhaust in order to minimize discharge of soot to the atmosphere. The soot particles accumulate in the channels of the DPF and are burned off at regular intervals through a process called regeneration. This prevents the DPF from clogging. The ECM commands the DPF regeneration after calculating various vehicle conditions such as DPF pressure difference, exhaust gas temperature, engine oil quality, engine speed, etc. Excessive accumulation of the soot in the DPF can cause a drop in the engine performance. During regeneration, additional fuel is injected via multiple post injections in order to increase the exhaust gas temperature. During this period, the DPF temperature is raised to approximately 600°C and the accumulated soot is oxidized or burned off into carbon dioxide (CO2).

Conditions for Running the DTC

    • The ignition is ON, or the engine is running.
    • The DTCs run continuously when the above condition is met.

Conditions for Setting the DTC

P2452 03, P2454

The ECM detects the DPF differential pressure sensor signal is less than 16 mV for greater than 2 seconds.

P2452 07, P2455

The ECM detects the DPF differential pressure sensor signal is greater than 4.9 volts for greater than 1 second.

Action Taken When the DTC Sets

DTCs P2452, P2454, and P2455 are type A DTCs.

Conditions for Clearing the DTC

DTCs P2452, P2454, and P2455 are type A DTCs.

Reference Information

Schematic Reference

Engine Controls Schematics

Connector End View Reference

Component Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

  1. Engine idling, observe the scan tool diesel particulate filter data parameter. The reading should be within 0-10 kPa (0-1.5 psi).
  2. Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.

Circuit/System Testing

  1. Ignition OFF, and the MAIN fuse removed, disconnect the harness connector at the DPF differential pressure sensor.
  2. Test for less than 5 ohms between the low reference circuit terminal 2 and ground.
  3. If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
  4. Install the MAIN fuse. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 1 and ground.
  5. If less than the specified range, test the 5-volt reference circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the ECM.
    If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
  6. Verify the scan tool DPF differential pressure sensor parameter is greater than 4.8 volts.
  7. If less than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the ECM.
  8. Install a 1A fused jumper wire between the signal circuit terminal 3 and ground. Verify the scan tool DPF differential pressure sensor parameter is less than 0.5 volts.
  9. If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
  10. If all circuits test normal, replace the DPF differential pressure sensor.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Exhaust Pressure Sensor Replacement
    •  Control Module References for ECM replacement, programming and setup.