GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

Was the HVAC Blower Controls System Check performed?

--

Go to Step 2

Go to HVAC Blower Controls System Check

2

  1. Place the heater and A/C controller mode switch in the Heat position.
  2. Place the heater and A/C controller blower motor switch in the LO position.
  3. Disconnect the blower motor resistor/relay connector.
  4. Place the ignition switch in the RUN position.
  5. Connect an unpowered test lamp to the blower motor resistor/relay connector, cavity E for CKT 60 (YEL), and ground.

Does the test lamp light?

--

Go to Step 3

Go to Step 4

3

Replace the blower motor resistor/relay.

Refer to Blower Motor Resistor Replacement .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

4

  1. Disconnect the heater and A/C controller C2 connector.
  2. Connect a J 39200 between the heater and A/C controller, pin A, and pin G.

Is continuity present?

--

Go to Step 5

Go to Step 6

5

Repair the open in CKT 60 (YEL) between the heater and A/C controller connector and the blower motor resistor/relay connector.

Refer to Wiring Repairs .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--

6

Replace the heater and A/C controller.

Refer to Control Assembly Replacement .

Is the repair complete?

--

Go to HVAC Blower Controls System Check

--