Step

Action

Value(s)

Yes

No

1

Did you perform the SIR Diagnostic System Check?

--

Go to Step 2

SIR Diagnostic System Check in SIR

2

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM between the Data Link Connector (DLC) terminals 9 and 4.

Is the voltage less than the specified value?

4-5 volts

Go to Step 4

Go to Step 3

3

Is the voltage greater than the specified value?

4-5 volts

Go to Step 6

SIR Diagnostic System Check in SIR

4

  1. Turn the ignition switch to the OFF position.
  2. Connect a J 39200 DMM between terminal 9 of the DLC and ground.

Is continuity present?

--

Go to Step 5

Go to Step 8

5

Locate and repair the short to ground in CKT 800 (TAN) between the Sensing and Diagnostic Module (SDM) and the DLC. Refer to SIR/SRS Wiring Repairs in Wiring Systems.

Is the repair complete?

--

SIR Diagnostic System Check in SIR

--

6

  1. Disconnect the SDM connector. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement in SIR.
  2. Turn the ignition switch to the RUN position.
  3. Connect a J 39200 DMM between terminal 9 of the DLC and ground.

Is the voltage greater than the specified value?

0 volts

Go to Step 7

Go to Step 8

7

Locate and repair the short to voltage in CKT 800 (TAN) between the Sensing and Diagnostic Module (SDM) and the DLC. Refer to SIR/SRS Wiring Repairs in Wiring Systems.

Is the repair complete?

--

SIR Diagnostic System Check in SIR

--

8

Perform the SDM Intergrity Check. Refer to Sensing and Diagnostic Module Integrity Check in SIR.

Did the SDM pass the check?

--

SIR Diagnostic System Check in SIR

Go to Step 9

9

Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement in SIR.

Is the repair complete?

--

SIR Diagnostic System Check in SIR

--