GM Service Manual Online
For 1990-2009 cars only

The SIR scan tool data definitions contain a brief description of all SIR related parameters available on the scan tool. The parameters that are available on the scan tool are listed below in alphabetical order.

Driver Seat Belt: The scan tool displays Buckled or Unbuckled. The signal from the drivers seat belt switch that the seat belt is fastened.

Driver Senselo: The scan tool displays 0-20 volts. The SDM measures the voltage of the driver low terminal voltage and displays the driver low terminal voltage as Driver Senselo.

Driver Resistance: The scan tool displays 0-6.3 ohms. The SDM performs the resistance measurement test once each ignition cycle and verifies the Ignition 1 and the 23 VLR voltages are within the normal ranges. Then the SDM sources a constant current to the driver deployment loop. The SDM then measures the voltage drop across the deployment loop and converts the measured voltage value to a driver deployment loop resistance value.

Driver VDIF: The scan tool displays 0-500 millivolts. The SDM measures the voltage difference between driver high and driver low and displays this voltage difference as Driver VDIF.

Ignition: The scan tool displays 0-25.5 volts. The ignition represents the system voltage which is measured by the SDM ignition feed.

Lamp Driver: The scan tool displays Internal or External. The warning lamp control method for a hard wired lamp is Internal. The warning lamp control method for a serial data controlled lamp is External.

Lamp Driver Feedback: The scan tool displays Active or Inactive. The warning lamp state is detected by the SDM.

Passenger Resistance: The scan tool displays 0-6.3 ohms. The SDM performs the resistance measurement test once each ignition cycle and verifies the Ignition 1 and 23 VLR voltages are within the normal ranges. Then the SDM sources a constant current to the passenger deployment loop. The SDM then measures the voltage drop across the deployment loop and converts the measured voltage value to a passenger deployment loop resistance value.

Passenger Senselo: The scan tool displays 0-20 volts. The SDM measures the voltage of the passenger low terminal voltage and displays the passenger low terminal voltage as Passenger Senselo.

Passenger VDIF: The scan tool displays 0-500 millivolts. The SDM measures the voltage difference between passenger high and passenger low and displays this voltage difference as Passenger VDIF.

Warning Lamp Control: The scan tool displays ON or OFF. The warning lamp state is commanded by the SDM.

Warning Lamp Cycles: The scan tool displays 0-125 cycles. The ignition cycles of the current warning lamp state.

Warning Lamp ON: The scan tool displays 0-182 hours. The SDM measures the continuous warning lamp ON time.