GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using the diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Circuit Description

The diesel particulate filter (DPF) captures diesel exhaust particulates, preventing their release into the atmosphere. When a high particulate loading condition occurs, the engine control module (ECM) will command a regeneration event to restore the DPF. If regeneration does not occur, the ECM will illuminate the DPF warning indicator. If the DPF indicator is ignored, the ECM will illuminate the MIL and revert to reduced engine power. Manual regeneration can be accomplished by pressing the DPF regeneration switch. During regeneration, the green DPF indicator will illuminate. The other DPF warning indicator will illuminate yellow when regeneration is required. When the same indicator turns red, immediate attention is required.

Reference Information

Schematic Reference

    •  Instrument Cluster Schematics
    •  Engine Controls Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

    •  Instrument Cluster Description and Operation
    •  Diesel Particulate Filter (DPF) System Description

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

  1. Ignition ON, verify that the DPF indicators illuminate during the self test when the ignition is turned ON.
  2. If either, or both the indicators do not illuminate, replace the IPC.
  3. Ignition OFF, disconnect the harness connector at the diesel particulate filter (DPF) regeneration switch.
  4. Ignition OFF, test for less than 1 ohm between the DPF regeneration switch ground circuit terminal A and ground.
  5. If greater than the specified range, test the ground circuit for an open/high resistance.
  6. Ignition ON, verify that the scan tool DPF Indicator Command is Off.
  7. If not the specified value, test the DPF regeneration switch signal circuit terminal C for a short to ground. If the circuit tests normal, replace the IPC.
  8. Install a 3-amp fused jumper wire between the DPF regeneration switch signal circuit terminal C and ground. Verify that the scan tool DPF Indicator Command Indicator is On.
  9. If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Accessory Switch Replacement
    •  Control Module References for the IPC replacement, setup, and programming