GM Service Manual Online
For 1990-2009 cars only

Tools Required

J 39400-A Halogen Leak Detector

Removal Procedure

  1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging .
  2. Remove the coolant recovery reservoir. Refer to Coolant Recovery Reservoir Replacement .

  3. Object Number: 924798  Size: SH
  4. Disconnect the low pressure sensor electrical connector (2).

  5. Object Number: 1190441  Size: SH
  6. Disconnect the blower motor assembly electrical connector.

  7. Object Number: 1190432  Size: SH
  8. Disconnect the blower motor resistor assembly electrical connector.

  9. Object Number: 1190579  Size: SH
  10. Remove the retaining nut (1) from the evaporator inlet tube.
  11. Remove the evaporator inlet tube retaining screw.
  12. Remove the evaporator inlet tube from the evaporator.
  13. Remove the O-ring seal.

  14. Object Number: 924801  Size: SH
  15. Remove the retaining nut (1) from the accumulator.
  16. Remove the accumulator from the evaporator.
  17. Remove the O-ring seal.

  18. Object Number: 1190546  Size: SH
  19. Remove the blower module assembly screws.
  20. Remove the blower module assembly.
  21. Remove the heater assembly. Refer to Heater Assembly Replacement .

  22. Object Number: 300824  Size: SH
  23. Remove the module assembly nuts (5).
  24. Remove the module assembly nuts (2).
  25. Remove the module from the vehicle.

Installation Procedure

  1. Install the module from the vehicle.
  2. Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 300824  Size: SH
  3. Install the module assembly nuts (2).
  4. Tighten
    Tighten the nuts to 6 N·m (53 lb in).

  5. Install the module assembly nuts (5).
  6. Tighten
    Tighten the nuts to 6 N·m (53 lb in).

  7. Install the heater assembly. Refer to Heater Assembly Replacement .

  8. Object Number: 1190546  Size: SH
  9. Install the evaporator and blower module assembly.
  10. Install the evaporator and blower module assembly retaining screws.
  11. Install new O-ring seals. Refer to O-Ring Replacement .

  12. Object Number: 924801  Size: SH
  13. Install the accumulator to the evaporator.
  14. Install the accumulator retaining nut (1).
  15. Tighten
    Tighten the nut to 18 N·m (13 lb ft).

  16. Install the evaporator inlet tube to the evaporator.

  17. Object Number: 1190579  Size: SH
  18. Install the evaporator inlet tube retaining nut (1).
  19. Tighten
    Tighten the nut to 16 N·m (12 lb ft).

  20. Install the evaporator inlet tube retaining screw.

  21. Object Number: 1190432  Size: SH
  22. Connect the blower motor resistor assembly electrical connector.

  23. Object Number: 1190441  Size: SH
  24. Connect the blower motor assembly electrical connector.

  25. Object Number: 924798  Size: SH
  26. Connect the low pressure sensor electrical connector (2).
  27. Install the coolant recovery reservoir. Refer to Coolant Recovery Reservoir Replacement .
  28. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging .
  29. Leak test the fittings of the components using the J 39400-A .