Circuit Description

The following DTCs are for the energy storage box (ESB) fan located in the energy storage box:

P0A82 is for the hybrid battery pack cooling fan stuck OFF.

The ESB module provides a variable voltage signal to the ESB fan through the fan speed signal circuit. The ESB fan changes speed based on the voltage from the ESB module.

DTC Descriptor

This diagnostic procedure supports the following DTC:

DTC P0A82 Hybrid Battery Pack Cooling Fan Stuck OFF

Conditions for Running the DTC

The ignition is ON.

Conditions for Setting the DTC

The energy storage control module (ESCM) determines that the ESB fan is stuck OFF.

Action Taken When the DTC Sets

    • The control module stores the DTC information into memory when the diagnostic runs and fails.
    • The malfunction indicator lamp (MIL) will not illuminate.
    • The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Failure Records.
    • The driver information center, if equipped, may display a message.

Conditions for Clearing the DTC

    • The DTC will become history if the ESCM no longer detects a fault.
    • The history DTC will clear after 100 fault-free ignition cycles.
    • The DTC can be cleared with a scan tool.

Step

Action

Values

Yes

No

Schematic Reference: Starting and Charging Schematics

Connector End View Reference: Engine Electrical Connector End Views

DEFINITION: The energy storage box (ESB) fan is inoperative.

1

Did you perform the Diagnostic System Check - Vehicle?

--

Go to Step 2

Go to Diagnostic System Check - Vehicle in Vehicle DTC Information

2

  1. Start the engine.
  2. Turn ON the auxiliary power outlets (APO) switch.

Does the ESB fan operate?

--

Go to Blower Motor Malfunction

Go to Step 3

3

  1. Turn OFF the ignition.
  2. Disconnect the energy storage box (ESB) fan connector.
  3. Start the engine.
  4. Turn ON the APO switch.
  5. Connect a test lamp between the ESB fan supply voltage circuit and the ESB fan ground circuit.

Does the test lamp illuminate?

--

Go to Step 8

Go to Step 4

4

Connect a test lamp between the low reference circuit of the ESB fan and battery positive voltage.

Does the test lamp illuminate?

--

Go to Step 5

Go to Step 7

5

Connect a test lamp between the battery positive voltage circuit of the ESB fan and a good ground.

Does the test lamp illuminate?

--

Go to Step 8

Go to Step 6

6

Repair the battery positive voltage circuit of the ESB fan. Refer to Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

--

7

Repair the ground circuit of the ESB fan. Refer to Wiring Repairs in Wiring Systems.

Did you complete the repair?

--

Go to Step 14

--

8

  1. Connect a volt meter between the ESB fan speed signal circuit and the low reference circuit of the ESB fan.
  2. Turn the APO switch ON and OFF.

Does the volt meter read between the correct values?

0 volts OFF and 7 volts ON

Go to Step 10

Go to Step 9

9

Test the ESB fan control circuit of the ESB fan for an open, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

Go to Step 11

10

Inspect for poor connections at the harness connector of the ESB fan. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

Go to Step 13

11

Inspect for poor connections at the harness connector of the energy storage control module (ESCM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

Go to Step 12

12

Replace the ESCM. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming.

Did you complete the replacement?

--

Go to Step 14

--

13

Replace the ESB fan. Refer to Generator Battery Vent Fan Replacement .

Did you complete the replacement?

--

Go to Step 14

--

14

Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 2