GM Service Manual Online
For 1990-2009 cars only

Special Tools

    • GE-48494 Power Electronics Pressure Test Adapter Kit
    • J 24460-01 Cooling System Pressure Tester

Removal Procedure


    Object Number: 1971290  Size: SH
  1. Remove the drive motor generator control module from the vehicle. Refer to Drive Motor Generator Control Module Assembly Replacement.
  2. Remove the temporary coolant pipe caps (1).
  3. Caution: The module must be drained of all residual coolant prior to disassembly. Failure to properly drain all residual coolant may cause electronic circuit damage to occur during disassembly.

    Important: Place a container under the coolant outlet pipe to capture the escaping coolant.

  4. Drain the drive motor generator control module assembly of residual coolant by applying 30 psi regulated compressed air to the coolant inlet pipe until no coolant remains.

  5. Object Number: 1971291  Size: SH
  6. Remove the drive motor generator power inverter control module (PIM) electronics cover fasteners (1).
  7. Remove the PIM electronics cover (2). Discard the cover seal (3).

  8. Object Number: 1971292  Size: SH

    Caution: Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

  9. Remove the HV dc accessory DC power control module (APM) terminal fasteners (1) utilizing a magnetic socket.

  10. Object Number: 1971293  Size: SH
  11. Temporarily install the PIM electronics cover (2) with 4 finger-tightened fasteners (1).

  12. Object Number: 1971295  Size: SH
  13. Rotate the drive motor generator control module assembly onto the PIM electronics cover.
  14. Remove the APM to PIM mounting fasteners (1).
  15. Remove the APM (2) and discard the coolant seal (3).
  16. Remove the drive motor generator power inverter coolant pipe bolts (4, 7).
  17. Remove the drive motor generator power inverter coolant pipes (5, 8).
  18. Remove and discard coolant seals (6, 9).

Installation Procedure


    Object Number: 1971295  Size: SH
  1. Install new APM coolant seal (3).
  2. Position the APM (2) onto the PIM ensuring the seals remain in place.
  3. Notice: Refer to Fastener Notice in the Preface section.

  4. Install the APM mounting fasteners (1).
  5. Tighten
    Tighten the mounting fasteners to 10 N·m (89 lb in).

    Important: Only use pre-mixed DEX-COOL® on the coolant pipe O-ring to aid in tube installation.

  6. Lubricate the new seals (6, 9) with pre-mixed DEX-COOL®.
  7. Install new seals (6, 9) onto the drive motor generator power inverter coolant pipes (5, 8).
  8. Install the coolant pipes (5, 8) to the PIM assembly with bolts (4, 7).
  9. Tighten
    Tighten the fasteners to 5 N·m (44 lb in).


    Object Number: 1971297  Size: SH
  10. Rotate the drive motor generator control module assembly onto the APM.
  11. Clamp the GE-48494 components (2, 3) to a coolant pipe.
  12. Plug the remaining coolant pipe with the GE-48494 plug and clamp (1).
  13. Apply the specified pressure with J 24460-01  (4).
  14. Pressure
    Apply 20 psi (138 kPa) pressure.

  15. Monitor the pressure tester gauge for 5 minutes and ensure that pressure remains at the specified value.
  16. • If the specified pressure cannot be maintained, disassemble the drive motor generator control module assembly and replace the coolant seal.
    • If pressure remains at the specified value, proceed to the next step.
  17. Remove all GE-48494 components.

  18. Object Number: 1971293  Size: SH
  19. Remove the PIM cover retaining bolts (1).
  20. Remove the PIM electronics cover (2).

  21. Object Number: 1971292  Size: SH

    Caution: Always remove and install the High Voltage terminal fasteners with a magnet tipped socket. Never touch the exposed electronic circuit board surface or components. Dropped fasteners or physical contact may result in electronic circuit board damage.

  22. Install the HV dc APM terminal fasteners (1) utilizing a magnetic socket.
  23. Tighten
    Tighten the terminal fasteners to 9 N·m (80 lb in).


    Object Number: 1971291  Size: SH
  24. Install a new PIM cover seal (3).
  25. Position the PIM cover (2) onto the PIM ensuring the seal remains in place.
  26. Install the PIM cover fasteners (1).
  27. Tighten
    Tighten the fasteners to 5 N·m (44 lb in).