GM Service Manual Online
For 1990-2009 cars only

Step

Action

Yes

No

Schematic Reference: HVAC Schematics

Connector End View Reference: HVAC Connector End Views

DEFINITION: The blower motor is ON while the HVAC control is in the OFF position.

1

Did you perform the Diagnostic System Check - Vehicle?

Go to Step 2

Go to Diagnostic System Check - Vehicle

2

  1. Turn ON the ignition, with the engine OFF.
  2. Turn OFF the HVAC controls.

Is the blower motor OFF?

Go to Testing for Intermittent Conditions and Poor Connections

Go to Step 3

3

Disconnect the HVAC control module.

Does the blower motor continue to operate?

Go to Step 4

Go to Step 8

4

Inspect or test the blower motor control circuit between the blower motor and the blower module for a short to ground. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

Go to Step 11

Go to Step 5

5

Test the blower motor speed control circuit between the HVAC control module and blower motor control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

Go to Step 11

Go to Step 6

6

Test the blower motor speed signal circuit for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

Go to Step 11

Go to Step 7

7

Inspect for poor connections at the harness connector of the blower motor control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .

Did you find and correct the condition?

Go to Step 11

Go to Step 9

8

Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .

Did you find and correct the condition?

Go to Step 11

Go to Step 10

9

Replace the blower motor control module. Refer to Blower Motor Control Processor Replacement .

Did you complete the replacement?

Go to Step 11

--

10

Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming.

Did you complete the replacement?

Go to Step 11

--

11

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 3