Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Did the backup lamps turn ON and OFF with each command? | -- | Go to Step 10 | Go to Step 3 |
3 |
Does the test light illuminate? | -- | Go to Step 4 | Go to Step 12 |
4 | Connect a test light between the switch side feed circuit of the Perim LP Relay and a good ground. Does the test light illuminate? | -- | Go to Step 5 | Go to Step 13 |
5 |
Did the test light turn ON and OFF with each command? | -- | Go to Step 6 | Go to Step 9 |
6 |
Did the backup lamps illuminate? | -- | Go to Step 7 | Go to Step 14 |
7 | Inspect for poor connections at the Perim LP relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 7 |
8 | Replace the Perim LP relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the replacement? | -- | Go to Step 16 | -- |
9 | Test the perim LP relay control circuit for high resistance, a short to voltage, or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 10 |
10 | Inspect for poor connections at the remote function actuator (RFA) module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 11 | |
11 | Replace the RFA module. Refer to RFA Module Replacement in Keyless Entry. Did you complete the replacement? | -- | Go to Step 16 | -- |
12 | Repair the open or high resistance in the perim LP relay coil side feed circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- |
13 | Repair the open or high resistance in the perim LP relay switch side feed circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- |
14 | Test the Perim LP relay switch side load circuit for high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 16 | Go to Step 15 |
15 | Repair the open or high resistance in the back up lamp ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |